QuickSert Wafer Style Flow Turbines :: Liquid and Gas

 
Blancett QuikSert® In-line Turbine Flow Meter  :: Sizes 3/8" to 10"
 
The Blancett QuikSert In-line Turbine Flow Meter provides the high accuracy and rigorous design of the standard Blancett turbine, but in a wafer-style mounting configuration. With a unique "between-the-flange" design, the need for mating flanges is eliminated, saving installation time and cost, and allowing for limited space requirements. The meter features a 316 stainless steel housing and rotor support, CD4MCU stainless steel rotor, and abrasion-resistant tungsten carbide rotor shaft and bearings. For fluid models, precision upstream and downstream flow straighteners ensure a high degree of measurement accuracy.
Specifications :
 

♦ Accuracy(Fluid)::       ±1% of reading for 7/8" and larger meters;
                                        ±1% of reading over the upper 70% of the measuring range for 3/8", 1/2" and 3/4" meters
 Accuracy(Gas)         :±2% of reading over the specified measuring range
 Repeatability::           ±0.1% (Fluid),±0.5% (Gas),
 Operating Temp::      -150 °F to +350 °F (-101 °C to +177 °C) (Fluid Standard)
                                         temperatures to +425 °F (+232 °C) (Fluid with high-temp pick-up)
                                         temperatures to -40 to +330 °F (-40 to +330 °C) (Gas)
♦ Turndown Ratio::       About 10:1
♦ End Connections::    Wafer-style, ASME/ANSI B16.5-1996