Electromagnetic Flow Meter:: DN50 Flange options, Rubber Liner (PTFE Option), AC / DC OPTIONS

SKU: BMF-50

Electromagnetic Flow Meter:: DN50
Budget Model
Calibrated reliable performance
Power, Liner, Display, Electrode :: See options

  • MATERIAL
  • DISPLAY MOUNTING
  • ELECTRODES
  • OUTPUT SIGNAL
  • LINER MATERIAL
  • POWER SUPPLY
  • COMMUNICATION
  • GROUNDING OPTIONS
  • FLANGES
  • $1411.25
  • $1693.50 inc VAT
Qty:  

Description

  • SKU
    BMF-50
 
Electromagnetic Flow Meter:: DN50
Budget Model
Calibrated reliable performance
Power, Liner, Display, Electrode options
 
The BMF range of Electromagnetic flow meters represent excellent value, offering a wide range of standard features and a selection of extra options. Supplied with multi-point calibration certificate and 12 month warranty as standard, these meters have a large installed user base and are the ideal choice when quality, reliability and cost of ownership are the major considerations
 
Features:

Rubber Liner (PTFE Option)
 IP65
Tube: Austenitic Stainless Steel
Body: Polyurethane Coated Steel
Flanges: Carbon Steel or Stainless on request
Electrodes: 316L (See options)
Grounding Electrode option
Bi-Directional Flow Measurement
Empty Pipe Detection
Max Temperature: See options
Max Pressure: See Options
 

Specification

     

    GENERAL SPECIFICATIONS

     

    Power Supply:

    110-240v AC (Optional: 20-36v DC)

     

    Diameters:

    DN10 to DN1000

     

    Repeatability: 

    ± 0.1%

     

    Power Consumption:

    <20W

     

    Accuracy:

    ± 0.5% accuracy of rate from 0.3-10 m/s

    ± 1.0% accuracy of rate from 0.1-0.3 m/s

     

    Display Mounting:

    Compact mounted or 

    Optional Remote Mounting from 10-100m

     

    Electrode Materials: 

    316L Stainless Steel as standard.

    Optional Titanium, Tantalum, Hastelloy C

    or Platinum-Iridium

     

    Liner Material:

    FEP/F46 only (DN10 to DN40)

    Hard Rubber or PTFE (DN50 to DN600) 

    Hard Rubber only (DN700 to DN1000)

     

    Minimum Fluid Conductivity:

    5.0 µS/cm

     

    Pressure Limits: 

    1.0 Bar; Optional 16 Bar, 25 Bar and 40 Bar

     

    Flow Direction:

    Unidirectional or Bidirectional

    2 separate totalizers (programmable)

     

    Flanges:

    Carbon Steel (ISO7005-1) or Optional 316 Stainless steel

    DIN as standard, optional ANSI or Sanitary connections

     

    Grounding Options: 

    316 Stainless Steel Grounding Rings

    Grounding Electrodes (same as measuring electrodes)

     

    Fluid Temperature:

    FEP/F46 or Hard Rubber: -20˚C to 60˚C

    PTFE: -20˚C to 120˚C (Optional Max 160˚C available)

     

    Noise Damping:

    Programmable

     

    Ambient Temperature:

    -4˚F to 140˚F (-20˚C to 60˚C)

     

    Analog Outputs: 

    Optional 4-20mA, 500ohms Max Load

     

    Coil Power:

    Pulsed DC

     

    Communications: 

    Optional MODBUS RS485 or HART

     

    Pipe Spool Material: 

    316 Stainless Steel

     

    Output Frequency: 

    Scaled Pulse Output,

    (open collector) Max 5Khz

     

    Meter Housing Material: 

    Polyurethane coated Carbon Steel

    Optional 316 Stainless Steel

     

    Pulse Width: 

    Programmable up to 500ms

     

    Zero-point Stability: 

    Automatic correction

     

     

Downloads