M2000 Electromagnetic Flow Meter:: DN10

SKU: 2M-A-004FECS3AAXS-SAAACXWWDBABXX
M2000 Electromagnetic Flow Meter:: DN10
Flow: 0.14 - 57 l/min
Accuracy ± 0.2%
PN16 Flanged connections (Various options available)
Stainles Steel body 304
Hastalloy Electrodes, PFA Liner (Various Liners and Electrode options)
Empty Pipe Detection + GND Electrode
Local LCD (Remote options) IP67 protection or optional IP68
115/230V AC Powered (9-36V DC option)
Pulse, Alarms, 4-20mA, Modbus (HART, Profibus DP, BACnet MS/TP, Modbus TCP/IP, EtherNet/IP and BACnet/IP options)
WRAS Approved / OIML Option
 
  • $2980.21
  • $3576.26 inc VAT
Qty:  

Description

  • Weight
    6.0000 kg
  • SKU
    2M-A-004FECS3AAXS-SAAACXWWDBABXX
 
M2000 Electromagnetic Flow Meter:: DN10
Flow: 0.14 - 57 l/min
Accuracy ± 0.2%
PN16 Flanged connections (Various options available)
Stainles Steel body 304
Hastalloy Electrodes, PFA Liner (Various Liners and Electrode options)
Empty Pipe Detection + GND Electrode
Local LCD (Remote options) IP67 protection or optional IP68
115/230V AC Powered (9-36V DC option)
Pulse, Alarms, 4-20mA, Modbus (HART, Profibus DP, BACnet MS/TP, Modbus TCP/IP, EtherNet/IP and BACnet/IP options)
WRAS Approved / OIML Option
 
*Various communication protocols
*Integral data logging option available
 
 
The M2000 can be chosen for a broad spectrum of applications and the wide selection of liner and electrode materials provide maximum compatibility and minimum maintenance over a long operating period.
In applications with limited space, the M2000 can be installed with zero straight pipe requirements and fulfils the accuracy according to OIML R49 and MID Annex MI-001.
 
Code breakdown for this model (Ask for a quote for any other version)
 
Product Type
  2M - M2000
Certification
  A - GENERAL SAFETY/PURPOSE
Meter Size
  004 - 3/8" / DN10
Process Connections
  FEC - EN1092-1 PN 16 Flanges
Base Material
  S3 - STAINLESS STEEL (304)
Liner Material
  A - PFA
Electrodes 
  A - Hastelloy C-22 (Standard / Measuring, Empty pipe & Grounding)
Grounding rings
  X - NO GND RINGS
Meter Lay Length
  S - STANDARD
Transmitter
  SA - SENSOR MOUNT; LOCAL DSP; AL ENCL; IP67
Power Supply
  AA - 110/220V AC
Hardware
  C - M20 THRD; POLY CABLE GLANDS
Junction Box
  X - NONE
Remote Cable Length
  WW - NONE
Input/Output Channel
  DBA - STD INPUT/OUTPUT
Communications
  B - STD COMMS RS232 MODBUS RTU
Wiring Method
  XX - NONE STD
Programming
  EA - Standard (Default Metric units)
Testing & Tagging
  F - 0,2%; 3-POINT; FACTORY CALIBRATED; STD

Specification

    M2000 Electromagnetic Flow Meter:: DN10
    Flow: 0.14 - 57 l/min
    Accuracy ± 0.2%
    PN16 Flanged connections (Various options available)
    Stainles Steel body 304
    Hastalloy Electrodes, PFA Liner (Various Liners and Electrode options)
    Empty Pipe Detection + GND Electrode
    Local LCD (Remote options) IP67 protection or optional IP68
    115/230V AC Powered (9-36V DC option)
    Pulse, Alarms, 4-20mA, Modbus (HART, Profibus DP, BACnet MS/TP, Modbus TCP/IP, EtherNet/IP and BACnet/IP options)
    WRAS Approved / OIML Option
     
    FEATURES
    • Accuracy ± 0.2%
    • Flow range 0.03…12 m/s
    • Sizes 1/4 …56 in. (6…1400 DN)
    • LCD display (local or remote options)
    • Power supply 92…275V AC, 9…36V DC
    • RS-232, RS-485 and RS-422 with (HART, Profibus DP, BACnet MS/TP, Modbus TCP/IP, EtherNet/IP and BACnet/IP options)
    • Integrated data logger opton
    • BEACON®/AquaCUE® connectivity
     
     
    Amplifier :
     
    M2000 
    Accuracy: ±0.2% of measured value
    Display: LCD showing actual flow rate with totalisers and status 
    (min/max alarm, pre-selection, flow direction, empty pipe error).
    Digital Outputs: 2x Open collector, 2x relay
    Analogue Outputs: 0/4 - 20 mA, 0/2 - 10mA
    Interface: Standard - ModBus RTU RS232/RS485
                      Optional - HART, ModBus TCP/IP, M-Bus, Profibus DP, BACnet MS/TP, EtherNet/IP, BACnet/IP
    Power Supply: 9 - 36 VDC or 92 - 275 VAC 
    Housing: IP67 Powder coated die-cast aluminium (Stainless options)
    Compact mounting on detector or remote mount kits.
    Data logger: Internal data logger (30 000 measuring values)
    Accessable by additional software and communication cable


     