QuickSert Wafer Style Flow Turbines :: Liquid and Gas
Blancett QuikSert® In-line Turbine Flow Meter :: Sizes 3/8" to 10"
The Blancett QuikSert In-line Turbine Flow Meter provides the high accuracy and rigorous design of the standard Blancett turbine, but in a wafer-style mounting configuration. With a unique "between-the-flange" design, the need for mating flanges is eliminated, saving installation time and cost, and allowing for limited space requirements. The meter features a 316 stainless steel housing and rotor support, CD4MCU stainless steel rotor, and abrasion-resistant tungsten carbide rotor shaft and bearings. For fluid models, precision upstream and downstream flow straighteners ensure a high degree of measurement accuracy.
Specifications :
♦ Accuracy(Fluid):: ±1% of reading for 7/8" and larger meters;
±1% of reading over the upper 70% of the measuring range for 3/8", 1/2" and 3/4" meters
♦ Accuracy(Gas) :±2% of reading over the specified measuring range
♦ Repeatability:: ±0.1% (Fluid),±0.5% (Gas),
♦ Operating Temp:: -150 °F to +350 °F (-101 °C to +177 °C) (Fluid Standard)
temperatures to +425 °F (+232 °C) (Fluid with high-temp pick-up)
temperatures to -40 to +330 °F (-40 to +330 °C) (Gas)
♦ Turndown Ratio:: About 10:1
♦ End Connections:: Wafer-style, ASME/ANSI B16.5-1996
:
from
to
Sort by:Recommended
Sort by:Recommended
- Blancett QuickSert Liquid Turbine Meter for Hazardous Locations :: 1" Line Size
SKU: B131C1" Line Size5 Flow Ranges: 2.3 – 189.2 l/min (0.6 – 50 USGal/min)Bore sizes from 3/8" to 1"Wafer style in between flange connections316L Stainless Steel constructionAccuracy: ±1% (above upper 70% of range fo 3/4" and smaller)Explosion Proof Model (Pickup and display extra)£848.89
£1018.67 inc VAT - Blancett QuickSert Liquid Turbine Meter for Hazardous Locations :: 2" Line Size
SKU: B132C2" Line Size6 Flow Ranges: 2.8 – 1514 l/min (0.75 – 400 USGal/min)Bore sizes from 1/2" to 2"Wafer style in between flange connections316L Stainless Steel constructionAccuracy: ±1% (above upper 70% of range fo 3/4" and smaller)Explosion Proof Model (Pickup and display extra)£1359.92
£1631.90 inc VAT - Blancett QuickSert Liquid Turbine Meter for Hazardous Locations :: 3" Line Size
SKU: B133C3" Line Size and Bore Size2 Flow Ranges: 227.2 – 3028.3 l/min (60 – 800 USGal/min)Wafer style in between flange connections316L Stainless Steel constructionAccuracy: ±1%Explosion Proof Model (Pickup and display extra)£2220.17
£2664.20 inc VAT - Blancett QuickSert Liquid Turbine Meter for Hazardous Locations :: 4" Line Size
SKU: B134C4" Line Size and Bore SizeFlow Range: 379 – 4542 l/min (100 – 1200 USGal/min)Wafer style in between flange connections316L Stainless Steel constructionAccuracy: ±1%Explosion Proof Model (Pickup and display extra)£3392.71
£4071.25 inc VAT - Blancett QuickSert Liquid Turbine Meter for Hazardous Locations :: 6" Line Size
SKU: B136C6" Line Size and Bore SizeFlow Range: 758 – 9463 l/min (200 – 2500 USGal/min)Wafer style in between flange connections316L Stainless Steel constructionAccuracy: ±1%Explosion Proof Model (Pickup and display extra)£6024.55
£7229.46 inc VAT