Hedland VA Flow meter for Oil and Petroleum: 3/4" BSP, Stainless Steel
SKU: HP702SHedland VA Flow Meter
For Oil and Petroleum Fluids
Stainless Steel Construction
Pressure up to 345 Bar / 5000 PSI
Pressure up to 345 Bar / 5000 PSI
3/4" BSP Connections
Flow ranges from 1-115 LPM
Calibrated on 0.876 SG
Ξ Optional Flow Switch and Test Kit version
Description
HP702S
Hedland VA Flow Meter
For Oil and Petroleum Fluids
Stainless Steel Construction
Pressure up to 345 Bar / 5000 PSI
Pressure up to 345 Bar / 5000 PSI
3/4" BSP Connections
Flow ranges from 1-115 LPM
Calibrated on 0.876 SG
Also available in Brass and Aluminium and with NPT or SAE connections (Please contact for more details)
The Hedland Flow Meter is a variable area (rotameter) instrument. A precision machined, sharp-edged Orifice is located within the piston assembly and forms an annular opening with the contoured metering cone. The piston assembly carries a cylindrical PPS/ ceramic magnet that is magnetically coupled to an external flow Indicator that moves precisely, in direct response to movement of the piston. A calibrated spring opposes flow in the forward direction. This spring decreases viscosity sensitivity and allows the flow meter to be used in any position, including inverted.
Features:
- Install in any position
- 360° rotatable guard/scale
- No electronics needed to obtain a reading
- No flow straighteners or special piping required
- Relatively insensitive to shock and vibration
- Magnetic coupling eliminates the need for mechanical linkages that wear, loosen and leak over the functional life of competitive meters
- Temperature up to 116 °C
- Pressure up to 241 bar max
- Accuracy ±7% full scale
- Repeatability +/- 1%
- Custom scale options to meet exact application requirements
Ξ Optional Flow Switch and Test Kit version
Application Examples
- Hydraulic Power Units
- Gear Boxes
- Test Benches
- Bearing Lubrication Flow Monitoring
- Hydraulic Linear Positioning
- Mineral Oils
- Hydraulic Tools and Components
- Power Steering Analyzing
- Transmission Fluid Analyzing
- Mobile Construction Equipment
- Petrol, Kerosene, Methanol Flow Monitoring
Specification
- Automatically signals alarm if flow is too high or too low
- Automatically opens or closes electrical circuits
- Triggers warning lights, buzzers and other devices
- Shuts down pumps and/or other equipment to protect your operation against permanent damage
- No mechanical linkage
- Automatically signals alarm if flow is too high or too low
- Full line of multi-functional remote flow indicators and transmitters
- Operate as part of a totally integrated electronic process control/data acquisition system
- Non-contact sensor electronics
- Electronic signal conditioning circuit
- Digital flow rate and total flow indication
- Proportional analog output
- In-field compensation for:
Hedland VA Flow Meter
For Oil and Petroleum Fluids
Aluminium Construction
3/4" BSP Connections
Flow ranges from 1-115 LPM
Calibrated on 0.876 SG
Features:
• Direct reading
• Install in any position
• 360° rotatable guard/scale
• Easier-to-read linear scale
• No flow straighteners or special piping required
• Relatively insensitive to shock and vibration
• Good viscosity stability
• Temperature up to 240 °F
• Accuracy ±2% full scale
• Repeatability ±1%
• Special scales available
• Calibrated for .876 S.G.
Flow-Alert Micro Switch
Enclosure:
Material: Anodized and epoxy powder-coated aluminum with polycarbonate lens.
Seals: Silicone gasket between enclosure and lens.
Viton O-rings between enclosure and flow meter body.
Connection: Pig-tail conductor (standard) with water-tight strain relief.
Other connections, including quick-disconnect, are available – consult factory for details.
Fastener: T303 SS
Rating: NEMA 12 & 13 (IP65)
Electrical Circuitry:
Adjustable Flow-Alert™ signal: single (1) or double (2) switch, pre-wired single-pole, double-throw (SPDT)
Adjustable over the entire flow measuring range.
10A @ 250 VAC maximum, 0.5A @ 125 VDC maximum.
The single switch model is supplied with a 34" length of 4-wire #18 AWG jacketed cable.
The double switch model is supplied with an 18" length of 7-wire #16 AWG jacketed cable.
Flow-Alert Reed Switch
Enclosure:
Material: Anodized and epoxy powder-coated aluminum with polycarbonate lens.
Seals: Silicone gasket between enclosure and lens.
Viton O-rings between enclosure and flow meter body.
Connection: 4-pin (Protection Class IP65)
Fastener: T303 SS
Rating: NEMA 12 & 13 (IP65)
Electrical Specifications:
Adjustable Flow-Alert™ signal: single (1) or double (2) reed switch, pre-wired singlepole,
single-throw (SPST-NO) normally open; or single-pole, single-throw (SPST-NC)
normally closed. UL recognized and CSA certified with high or low flow limit setting,
adjustable over the entire flow measuring range.
MR Flow Transmitter
Specific gravity of all fluids
Viscosity of petroleum based fluids
Materials:
2024 - T351 Anodized aluminum body, piston and cone
C360 Brass body, piston and cone
T303 Stainless body, 2024 - T351 Anodized aluminum piston and cone
(Oil, PE, WBF, & Air meters)
T303 Stainless body, C360 Brass piston and cone (Water meters)
T316 Stainless body, piston and cone
Enclosure:
Material: Anodized and epoxy powder-coated aluminum with
polycarbonate lens
Seals: Silicone gaskets between enclosure and lens
Viton® O-rings between enclosure and flow
meter body
Connection: 4-pin (Protection Class IP65) standard, see Figure 2
Other connections available - consult factory for details
Fasteners: T303 SS
Rating: NEMA 12 & 13 (IP 52/54)
Electrical Specifications:
Power Requirement: 0-5 VDC Output: 10-30 VDC @ 0.75W maximum
0-10 VDC Output: 12-30 VDC @ 0.75W maximum
4-20 mA Output: loop-powered, 30 VDC maximum
Power Consumption: 25 mA maximum
Analog Outputs: 0-5 VDC and 0-10 VDC into 10,000 Ohms minimum
4-20 mA into 1000 Ohms maximum
Circuit Protection: Reverse polarity and current limiting
Transmission Distance: 4-20 mA limited by cable resistance
0-5 VDC and 0-10 VDC 1000 feet (300 m) maximum
Isolation: Inherently isolated from the piping system
Display: Fixed or toggle modes of operation for rate and totalizer display
8 digit, 0.70" high numeric display for rate and total
8 digit, 0.35" high alphanumeric display for units and setup
Test Kit
Includes Pressure gauge and Load valve
Pressure Gauge: Glycerin dampened, 0 – 5000 psi / 0 – 345 bar pressure range available
Load Valve: Needle Valve produces ΔP up to 5000 psi / 345 bar
Reverse Flow By-Pass
Flow in reverse direction cases lower cone shuttle to shift moving below the sharp-edged piston orifice.
This shift allows the fluid to flow freely in the reverse direction.