MIDF Magflow Hygienic :: Sanitary Electromagnetic Flow Meter :: DN15

MIDF Magflow Hygienic :: Sanitary Electromagnetic Flow Meter :: DN15

SKU: 1M-A-005TABS7PAXS-SAAACXWWDBARXX
MIDF Sanitary Electromagnetic Flow Meter:: DN15
Flow: 0.32 - 127 l/min
High accuracy and minimal pressure loss
Tri-Clamp BS4825 (Other Options)
316 Stainless Steel Body, PTFE Liner
Hastelloy C Measuring & Empty Pipe Electrodes
M1000 Local Display (Remote options)
Choice of output options  
115/230V AC Powered (9-36V DC Option)
IP67 protection or optional IP68
  • £2126.30
  • £2551.56 inc VAT
 

Description


MIDF
Hygienic Magflow Meter:: DN15
 
Flow: 0.32 - 127 l/min
High accuracy and minimal pressure loss
Tri-Clamp BS4825 (Other Options)
316 Stainless Steel Body, PTFE Liner
Hastelloy C Measuring & Empty Pipe Electrodes
M1000 Local Display (Remote options)
Choice of output options  
115/230V AC Powered (9-36V DC Option)
IP67 protection or optional IP68
 
*Various communication protocols
*Optional Stainless Steel Amplifier (MS1000)
*Integral data logging options available
 
 
 
The MIDF is a ruggedly constructed electromagnetic flow detector
designed for use in the most sanitary applications. Match it with
the M1000 or M2000 LCD amplifier to provide a high performance
flow meter for all conductive fluid applications.
 
  • Highly accurate 0.3% with M1000 or 0.2% with M2000 amplifier >5m/s
  • Bi-directional measurement
  • Repeatability of 0.1% of full scale
  • Engineered for long lasting performance
  • No moving parts that wear and tear
  • Robust construction in Stainless Steel 

Specification

     
     MIDF Hygienic Magflow Meter:: DN15
     
    •  Highly accurate; ±0.3% with M1000 or ±0.2% with M2000 amplifier 
       Bi-directional measurement
       Repeatability of 0.1% of full scale
       Engineered for long lasting performance
       No moving parts that wear out
       Robust construction in Stainless Steel
     
    Product Type
     1M - M1000
    Certification
     A - GENERAL SAFETY/PURPOSE
    Meter Size
     005 - 1/2" / DN15
    Process Connections
     TAB - TRI-CLAMP (BS 4825)
    Base Material
     S7 - STAINLESS STEEL (316)
    Liner Material
     P - PTFE
    Electrodes 
     A - Hastelloy C-22 (Standard / Measuring, Empty pipe & Grounding)
    Grounding rings
     X - NO GND RINGS
    Meter Lay Length
     S - STANDARD
    Transmitter
     SA - SENSOR MOUNT; LOCAL DSP; AL ENCL; IP67
    Power Supply
     AA - 110/220V AC
    Hardware
     C - M20 THRD; POLY CABLE GLANDS
    Junction Box
     X - NONE
    Remote Cable Length
     WW - NONE
    Input/Output Channel
     DBA - STD INPUT/OUTPUT
    Communications
     R - STD COMMS
    Wiring Method
     XX - NONE STD
    Programming
     EA - Standard (Default Metric units)
    Testing & Tagging
     F - 0,3%; 3-POINT; FACTORY CALIBRATED
     
    Amplifiers :
     
    M1000 / MS1000
    Accuracy: ±0.3% of measured value
    Display: LCD showing actual flow rate with totalisers and status 
    (min/max alarm, pre-selection, flow direction, empty pipe error).
    Digital Outputs: 2x Open collector, 1x relay
    Analogue Outputs: 0/4 - 20 mA, 0 - 10mA
    Interface: Standard - ModBus RTU RS232/RS485, ModBus/TCP
                      Optional - HART, M-Bus
    Power Supply: 9 - 36 VDC or 92 - 275 VAC 
    Housing: IP67 Powder coated die-cast aluminium
    Compact mounting on detector or remote mount kits.
    Data logger: Internal data logger (30 000 measuring values)
                           Accessable by additional software and communication cable

    M2000
    Accuracy: ±0.2% of measured value
    Display: LCD showing actual flow rate with totalisers and status 
    (min/max alarm, pre-selection, flow direction, empty pipe error).
    Digital Outputs: 4x Open collector, 2x relay
    Analogue Outputs: 0/4 - 20 mA, 0 - 10mA
    Interface: Standard - ModBus RTU RS232
                      Optional - RS485, HART, Profibus DP, M-Bus
    Power Supply: 9 - 36 VDC or 85 - 265 VAC
    Housing: IP67 Powder coated die-cast aluminium
    Compact mounting on detector or remote mount kits.
    Data logger: Optional 10 000 measuring values (requires additional memory card)
                           Accessable by additional software and communication cable

Downloads

News

All news