Hedland VA Flow meter for Water: 1/2" BSP, Brass

SKU: HP606B
Hedland VA Flow Meter
For Water and Other Liquids
Brass Construction
1/2" BSP Connections
Flow ranges from 0.5 - 56 LPM
Calibrated on 1.0 SG
Optional Flow Switches
  • Flow Range
  • Switches
  • $475.46
  • $570.56 inc VAT
Qty:  

Description

  • Weight
    1.1800 kg
  • SKU
    HP606B
 
HP606B
 
Hedland VA Flow Meter
For Water and Other Liquids
Brass Construction
1/2" BSP Connections
Flow ranges from 0.5 - 56 LPM
Calibrated on 1.0 SG

Install in any position
360° rotatable guard/scale
No flow straighteners or special piping required
Temperature up to 116 °C
Pressure up to 241 bar max
Accuracy ±2% full scale
 
 
Optional Flow Switches and digital transmitter
 
Available in Stainless Steel and with NPT or SAE connections (Please contact for more details)

Specification

     
    Hedland VA Flow Meter
    For Water and Other Liquids
    Brass Construction
    1/2" BSP Connections
    Flow ranges from 0.5 - 3.75 LPM
    Calibrated on 1.0 SG

    Features:
    • Direct reading
    • Install in any position
    • 360° rotatable guard/scale
    • Easier-to-read linear scale
    • No flow straighteners or special piping required
    • Relatively insensitive to shock and vibration
    • Good viscosity stability
    • Temperature up to 240 °F
    • Accuracy ±2% full scale
    • Repeatability ±1%
    • Special scales available
    • Calibrated for 1.0 S.G.


    Flow-Alert Micro Switch
    • Automatically signals alarm if flow is too high or too low
    • Automatically opens or closes electrical circuits
    • Triggers warning lights, buzzers and other devices
    • Shuts down pumps and/or other equipment to protect your operation against permanent damage
     
    Enclosure:
    Material: Anodized and epoxy powder-coated aluminum with polycarbonate lens.
    Seals: Silicone gasket between enclosure and lens.
    Viton  O-rings between enclosure and flow meter body.
    Connection: Pig-tail conductor (standard) with water-tight strain relief.
    Other connections, including quick-disconnect, are available – consult factory for details.
    Fastener: T303 SS
    Rating: NEMA 12 & 13 (IP65)
     
    Electrical Circuitry:
    Adjustable Flow-Alert™ signal: single (1) or double (2) switch, pre-wired single-pole, double-throw (SPDT)
    Adjustable over the entire flow measuring range.
    10A @ 250 VAC maximum, 0.5A @ 125 VDC maximum.
    The single switch model is supplied with a 34" length of 4-wire #18 AWG jacketed cable.
    The double switch model is supplied with an 18" length of 7-wire #16 AWG jacketed cable.
     
     
    Flow-Alert Reed Switch
    • No mechanical linkage
    • Automatically signals alarm if flow is too high or too low
     
    Enclosure:
    Material: Anodized and epoxy powder-coated aluminum with polycarbonate lens.
    Seals: Silicone gasket between enclosure and lens.
    Viton O-rings between enclosure and flow meter body.
    Connection: 4-pin (Protection Class IP65)
    Fastener: T303 SS
    Rating: NEMA 12 & 13 (IP65)
     
     
    Electrical Specifications:
    Adjustable Flow-Alert™ signal: single (1) or double (2) reed switch, pre-wired singlepole,
    single-throw (SPST-NO) normally open; or single-pole, single-throw (SPST-NC)
    normally closed. UL recognized and CSA certified with high or low flow limit setting,
    adjustable over the entire flow measuring range.
     
     
    MR Flow Transmitter
    • Full line of multi-functional remote flow indicators and transmitters
    • Operate as part of a totally integrated electronic process control/data acquisition system
    • Non-contact sensor electronics
    • Electronic signal conditioning circuit
    • Digital flow rate and total flow indication
    • Proportional analog output
    • In-field compensation for:
    Specific gravity of all fluids
    Viscosity of petroleum based fluids
     
     
    Materials:
    2024 - T351 Anodized aluminum body, piston and cone
    C360 Brass body, piston and cone
    T303 Stainless body, 2024 - T351 Anodized aluminum piston and cone
    (Oil, PE, WBF, & Air meters)
    T303 Stainless body, C360 Brass piston and cone (Water meters)
    T316 Stainless body, piston and cone
     
     
    Enclosure:
    Material: Anodized and epoxy powder-coated aluminum with
    polycarbonate lens
    Seals: Silicone gaskets between enclosure and lens
    Viton® O-rings between enclosure and flow
    meter body
    Connection: 4-pin (Protection Class IP65) standard, see Figure 2
    Other connections available - consult factory for details
    Fasteners: T303 SS
    Rating: NEMA 12 & 13 (IP 52/54)
     
    Electrical Specifications:
    Power Requirement: 0-5 VDC Output: 10-30 VDC @ 0.75W maximum
    0-10 VDC Output: 12-30 VDC @ 0.75W maximum
    4-20 mA Output: loop-powered, 30 VDC maximum
    Power Consumption: 25 mA maximum
    Analog Outputs: 0-5 VDC and 0-10 VDC into 10,000 Ohms minimum
    4-20 mA into 1000 Ohms maximum
    Circuit Protection: Reverse polarity and current limiting
    Transmission Distance: 4-20 mA limited by cable resistance
    0-5 VDC and 0-10 VDC 1000 feet (300 m) maximum
    Isolation: Inherently isolated from the piping system
    Display: Fixed or toggle modes of operation for rate and totalizer display
    8 digit, 0.70" high numeric display for rate and total
    8 digit, 0.35" high alphanumeric display for units and setup

Downloads